• VFD M3 Series 0.75kw 1.5kw 2.2kw 3kw 3.7kw 5.5kw 7.5kw 380V AC
  • VFD M3 Series 0.75kw 1.5kw 2.2kw 3kw 3.7kw 5.5kw 7.5kw 380V AC
  • VFD M3 Series 0.75kw 1.5kw 2.2kw 3kw 3.7kw 5.5kw 7.5kw 380V AC
  • VFD M3 Series 0.75kw 1.5kw 2.2kw 3kw 3.7kw 5.5kw 7.5kw 380V AC
  • VFD M3 Series 0.75kw 1.5kw 2.2kw 3kw 3.7kw 5.5kw 7.5kw 380V AC
  • VFD M3 Series 0.75kw 1.5kw 2.2kw 3kw 3.7kw 5.5kw 7.5kw 380V AC

VFD M3 Series 0.75kw 1.5kw 2.2kw 3kw 3.7kw 5.5kw 7.5kw 380V AC

Application: Three Phase Transducer, Single-phase Transducer
Output Type: Dual
Principle of Work: V/F Control Transducer
Main Circuit Type: Voltage
Voltage of Power Supply: Medium Voltage Variable-Frequency Drive
Link of Transformation: AC-DC-AC Variable-Frequency Drive
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
M
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Constant Torque Universal Type
Brand
Silinman
Transport Package
Cartons
Trademark
Silinman
Origin
Zhejiang Province, China
HS Code
8504409999
Production Capacity
120000PCS/Year

Product Description

VFD M3 Series 0.75kw 1.5kw 2.2kw 3kw 3.7kw 5.5kw 7.5kw 380V AC
M3 Series VFD,optimized V/F control system,less motor noise,strong fast current limiting function,with 485 communication,keyboard support quick plug and unplug.

Technical Characteristics:

Power range:0.75kw-7.5kw
V/F control,square multipoint VF
Low speed can reach 150% output torque
Support modbus 485 communication
Small size, convenient installation
8 Segment speed, simple PLC, PID control

Product Specifications:
Function description Specifications
Input Rated voltage;frequency AC,220v or 380v;50/60Hz
Allowable voltage working range Fluctuation range: ≤±20%, voltage imbalance rate: ≤3%, frequency: ≤5%
Output Rated voltage AC 0~220v or 0~380v
Rated frequency 0~999.9Hz
Overload capacity 100% rated current 1 minute
Control performance Control mode V/F
Modulation method Space voltage PWM modulation
Speed range 1:100
Starting torque 150% rated torque at 3.0Hz
Stability accuracy ≤±0.2% rated synchronous speed
Speed fluctuation ≤±0.5% rated synchronous speed
Torque response ≤50ms
Torque control Support torque control in vector control mode without PG, torque control accuracy ±5%
Frequency accuracy Digital setting: maximum frequency multiplied by±0.01%; analog setting: maximum frequency multiplied by±0.2%
Frequency resolution Digital setting: 0.01Hz; Analog setting: maximum frequency multiplied by±0.05%
Torque boost Automatic torque boost; manual torque boost 0.1%~30.0%
V/F curve Three methods: linear curve, square curve, multi-point VF curve
Acceleration and deceleration curve Linear acceleration and deceleration, time unit (minute/second), up to 999.9 seconds
DC braking Start frequency of DC braking at stop: 0.00~50.00Hz   Braking time: 0.0~30.0s; Braking current: 0.0%~50.0% of rated current
Automatic voltage adjustment AVR When the grid voltage changes, it can automatically keep the output voltage constant
Automatic current limit Automatically limit the current during operation to prevent frequent over-current faults
Voltage stall Control the voltage during deceleration to prevent frequency overvoltage faults
Automatic carrier adjustment According to the load characteristics and temperature characteristics, the carrier frequency is automatically adjusted, and a variety of carrier modes are available
Personalization function Frequency combination function Run command channel and frequency given channel can be combined arbitrarily
Jog Jog frequency range: 0.00Hz~50.00Hz
Multi-speed Built-in simple PLC or control terminal to realize multi-speed operation
Built-in closed loop control Conveniently form a closed-loop control Xirong
Water supply burst detection Tube burst detection delay time, high pressure detection threshold, low pressure detection threshold
Run function Run command channel Operation panel, control terminal, serial port, can be switched in a variety of ways
Frequency given channel 2 kinds of numerical setting, analog voltage setting, analog current setting, pulse setting, digital setting
Fixed, multi-stage speed setting, etc.
Auxiliary frequency setting Realize flexible auxiliary frequency fine-tuning and frequency synthesis
Pulse output terminal 0~50Hz pulse square wave signal output, which can realize the output of set frequency and output physical quantity
Analog output terminal 2 channels of analog output, the output orientation can be flexibly set between 0~20mA or 0~10V, which can be implemented
Now set the output of physical quantities such as frequency and output frequency
Operation panel LED display Display 26 parameters such as set frequency, output frequency, output voltage, output current, etc.
Buttons Button function selection Define the scope of some buttons to prevent misoperation
Protection Protectio function Phase loss protection, over current protection, over voltage protection, over voltage protection, over heat protection, overload and under protection, load drop protection, etc.
Environment Use place The room is not exposed to direct sunlight, dust, corrosive gas, flammable gas, oil mist, water steam, dripping or salt, etc.
Altitude Derating for use above 1000 meters, derating 10% for every 1000 meters
Ambient temperature -10ºC ~ +40ºC (the ambient temperature is between 40ºC ~ 50ºC, please use with derating)
temperature 5%~95%RH, no condensation
shock Less than 5.9/s2(0.6g)
storage temperature -40ºC ~ +70ºC
Structure Protection level IP20
cooling method Air-cooled, with fan control
Efficiency 7.5KW and below ≥93%

M3 Series VFD Models:
Models Power capacity KVA Input current  A Ouput current  A Adapted motor KW
Single phase  220v M300R7G1 1.4 4.0 3.7 0.75
M301R5G1 2.6 7.0 7.0 1.5
M302R2G1 3.8 10.0 9.6 2.2
M304R0G1 8.8 16.0 16.5 4.0
M305R5G1 11 28.0 25.0 5.5
3phase          380v M300R7G3 1.5 2.3 2.1 0.75
M301R5G3 3.7 3.7 3.7 1.5
M302R2G3 4.7 5.0 5.0 2.2
M304R0G3 5.9 10.5 9.0 4.0
M305R5G3 8.9 14.6 13.0 5.5
M307R5G3 11 20 17.0 7.5

M3 Series VFD wiring diagram:
VFD M3 Series 0.75kw 1.5kw 2.2kw 3kw 3.7kw 5.5kw 7.5kw 380V AC

Description of Control Circuit Terminals:
Control circuit terminal description
Type Terminal label Function description Specification
Multifunctionaldigital input terminal X1 It is effective when X (X1, X2, X3, X4, X5) and GND are short-circuited, and their functions are respectively set by parameters P2.13~P2.17. (Common: GND) INPUT, 0~10V level signal, low level effective, 5mA.
X2    
X3    
X4    
X5    
Digital signal output terminal Y1 Multi-function programmable open-collector output, programmable defined as a switch output terminal with multiple functions. (Common: GND) OUTPUT, the maximum load current is not more than 50mA.
Analog output input terminal ACI ACI accepts current input, AVI only accepts voltage input. See the description of function code P2.00~P2.09 for the range setting. (Reference ground: GND) INPUT, input voltage range: 0~10V (input impedance: 100KΩ), input current range: 0~20mA (input impedance: 500Ω).
AVI    
AO AO provides analog voltage/current output, which can represent 6 physical quantities. The output voltage and current are selected by jumper J2 (AO jumper terminal). The factory default output voltage. If you want to output current, you only need to jumper cap short. Connect the middle and the other end. See function code for details
F2.10 description. (Reference ground: GND)
OUTPUT, 0~10V DC voltage. The output voltage of the AO terminal is the PWM waveform from the central processing unit. The output voltage is proportional to the width of the PWM waveform.
Relay output terminal TA There are up to 14 types of programmable relay terminals TA and TC outputs. For details, please refer to F2.20 output terminal function introduction. TA-TB: normally closed; TA-TC: normally open. Contact capacity: 250VAC/2A (COSФ=1); 250VAC/1A (COSФ=0.4), 30VDC/1A.
TB    
TC    
Power interface 10V 10V is the common power supply for the circuit of the analog input terminal Maximum output current 20mA.
12V 12V is the common power supply of the circuit of the digital signal input terminal Maximum output current 100mA.
GND Analog signal and 10V, digital signal and 12V power reference ground. Analog signal,digital signal common ground
Communication interface 485+ RS485 signal + terminal Standard RS485 communication interface, not isolated from GND, please use twisted pair or shielded wire
485- RS485 signal - terminal  
       

M3 Series VFD Operation Panel:
VFD M3 Series 0.75kw 1.5kw 2.2kw 3kw 3.7kw 5.5kw 7.5kw 380V AC

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2023

Suppliers with verified business licenses

Trading Company
Number of Employees
10
Year of Establishment
2021-07-16